{"id":42802,"date":"2021-02-20T17:49:31","date_gmt":"2021-02-20T09:49:31","guid":{"rendered":"https:\/\/www.optcore.net\/?p=42802"},"modified":"2023-11-23T11:02:46","modified_gmt":"2023-11-23T03:02:46","slug":"understanding-the-optical-transceiver-quality-testing","status":"publish","type":"post","link":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/","title":{"rendered":"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico"},"content":{"rendered":"\n<p>Es bien sabido que el&nbsp;<a href=\"https:\/\/www.optcore.net\/tag\/optical-transceiver\/\">transceptor \u00f3ptico<\/a>&nbsp;es una parte importante de&nbsp;<a href=\"https:\/\/www.optcore.net\/product-category\/fiber-patch-cables\/\">la red de<\/a>&nbsp;comunicaci\u00f3n de&nbsp;<a href=\"https:\/\/www.optcore.net\/product-category\/fiber-patch-cables\/\">fibra \u00f3ptica<\/a>&nbsp;.&nbsp;Por lo general, todos est\u00e1n muy preocupados por el rendimiento del conmutador Ethernet, sin embargo, pueden ignorar la calidad de los componentes importantes: el transceptor \u00f3ptico, el precio se ha convertido en el \u00fanico factor en la compra.&nbsp;Pero la verdad es que el mercado ahora est\u00e1 inundado de transceptores de baja calidad, y es dif\u00edcil para los usuarios comunes discernir los transceptores \u00f3pticos de alta calidad.<\/p>\n\n\n\n<p>La calidad del transceptor \u00f3ptico determina el rendimiento de la transmisi\u00f3n de la red, que puede reducirse significativamente una vez que se corta el trabajo.&nbsp;Al igual que otros aparatos de alta tecnolog\u00eda, el transceptor \u00f3ptico se somete a rigurosos procedimientos de prueba e inspecci\u00f3n de calidad en su proceso de fabricaci\u00f3n, como pruebas de potencia \u00f3ptica, pruebas de sensibilidad, pruebas de diagramas de ojos, pruebas de envejecimiento, pruebas de m\u00e1quinas reales, detecci\u00f3n de la cara del extremo de la fibra, etc. Estos procesos involucran cada etapa del proceso de producci\u00f3n para asegurar los mejores resultados.&nbsp;Si alg\u00fan programa falla, el transceptor \u00f3ptico ser\u00e1 rechazado y devuelto a la l\u00ednea de producci\u00f3n para trabajos pesados.<\/p>\n\n\n\n<p>Entonces, \u00bfc\u00f3mo se prueban los par\u00e1metros de rendimiento del transceptor \u00f3ptico?<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Medici\u00f3n de potencia \u00f3ptica de salida media del transceptor<\/h3>\n\n\n\n<p>El puerto de transmisi\u00f3n del transceptor \u00f3ptico consta de una fuente de luz y un circuito electr\u00f3nico relacionado.&nbsp;Los diodos emisores de luz (LED) basados \u200b\u200ben semiconductores y los diodos l\u00e1ser se utilizan como fuentes de luz en transistores \u00f3pticos.&nbsp;Los l\u00e1seres LED y de emisi\u00f3n de superficie de cavidad vertical (VCSEL) se utilizan normalmente para transmisores en redes locales y locales, mientras que los l\u00e1seres Fabry-Perot (FP) y los l\u00e1seres de retroalimentaci\u00f3n distribuida (DFB) se utilizan para transmisores para redes Metro y de larga distancia.<\/p>\n\n\n\n<p>En la comunicaci\u00f3n \u00f3ptica, las fuentes de luz est\u00e1n moduladas en intensidad, que es un proceso de aplicaci\u00f3n de corriente variada al l\u00e1ser para cambiar el nivel de potencia de salida.&nbsp;Como se ilustra en la Figura 1, un nivel de potencia finito representa un cero l\u00f3gico en lugar de una verdadera ausencia total de potencia.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"490\" height=\"337\" src=\"https:\/\/www.optcore.net\/wp-content\/uploads\/optical-power-meter-blog.jpg.webp\" alt=\"\" class=\"wp-image-42785\" srcset=\"https:\/\/www.optcore.net\/wp-content\/uploads\/optical-power-meter-blog.jpg 490w, https:\/\/www.optcore.net\/wp-content\/uploads\/optical-power-meter-blog-250x172.jpg 250w\" sizes=\"auto, (max-width: 490px) 100vw, 490px\" \/><\/figure>\n\n\n\n<p>La potencia \u00f3ptica de salida promedio es un par\u00e1metro importante del transmisor, que afecta directamente la calidad de comunicaci\u00f3n del m\u00f3dulo.&nbsp;Es la potencia \u00f3ptica media del receptor en condiciones normales de funcionamiento.&nbsp;El medidor de potencia \u00f3ptica permite una medici\u00f3n de potencia \u00f3ptica de salida promedio para probar la potencia \u00f3ptica en el extremo de la transmisi\u00f3n.&nbsp;En el caso de transmisores para transmisi\u00f3n a larga distancia, la potencia \u00f3ptica media es mayor que la potencia \u00f3ptica de entrada m\u00e1xima.<\/p>\n\n\n\n<p>La potencia \u00f3ptica media se mide con un&nbsp;<a href=\"https:\/\/www.optcore.net\/product-category\/optical-power-meter\/\">medidor de potencia \u00f3ptica<\/a>&nbsp;.&nbsp;La unidad de medida suele expresarse en dBm, una relaci\u00f3n logar\u00edtmica del nivel de potencia a 1 mW.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Medici\u00f3n de la relaci\u00f3n de extinci\u00f3n del transceptor<\/h3>\n\n\n\n<p>La relaci\u00f3n de extinci\u00f3n, cuando se utiliza para describir el rendimiento de un transmisor \u00f3ptico utilizado en comunicaciones digitales, es simplemente la relaci\u00f3n entre la energ\u00eda (potencia) utilizada para transmitir un nivel l\u00f3gico &#8216;1&#8217; y la energ\u00eda utilizada para transmitir un nivel l\u00f3gico &#8216;0 &#8216;.&nbsp;Para una descripci\u00f3n gr\u00e1fica, el diagrama de ojo se usa com\u00fanmente como se muestra en la Figura 2.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"428\" height=\"108\" src=\"https:\/\/www.optcore.net\/wp-content\/uploads\/Extinction-Ratio-Measurement.png.webp\" alt=\"\" class=\"wp-image-42791\" srcset=\"https:\/\/www.optcore.net\/wp-content\/uploads\/Extinction-Ratio-Measurement.png 428w, https:\/\/www.optcore.net\/wp-content\/uploads\/Extinction-Ratio-Measurement-250x63.png 250w\" sizes=\"auto, (max-width: 428px) 100vw, 428px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Medici\u00f3n de amplitud de modulaci\u00f3n \u00f3ptica<\/h3>\n\n\n\n<p>La amplitud de modulaci\u00f3n \u00f3ptica (OMA) se utiliza para medir la diferencia entre los dos niveles de potencia \u00f3ptica generados por la fuente de alimentaci\u00f3n, por ejemplo, P1 (cuando la fuente de luz est\u00e1 encendida) y P0 (cuando la fuente de luz est\u00e1 apagada).&nbsp;Con OMA, se puede utilizar una relaci\u00f3n de iluminaci\u00f3n baja o alta, siempre que los ojos del transmisor est\u00e9n seguros y no sobrecarguen el receptor.<\/p>\n\n\n\n<p>La figura 3 muestra OMA en un diagrama de ojo estresado de una se\u00f1al \u00f3ptica.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"517\" height=\"474\" src=\"https:\/\/www.optcore.net\/wp-content\/uploads\/depicts-OMA-in-a-stressed-eye-diagram-of-an-optical-signal.jpg.webp\" alt=\"\" class=\"wp-image-42793\" srcset=\"https:\/\/www.optcore.net\/wp-content\/uploads\/depicts-OMA-in-a-stressed-eye-diagram-of-an-optical-signal.jpg 517w, https:\/\/www.optcore.net\/wp-content\/uploads\/depicts-OMA-in-a-stressed-eye-diagram-of-an-optical-signal-510x468.jpg 510w, https:\/\/www.optcore.net\/wp-content\/uploads\/depicts-OMA-in-a-stressed-eye-diagram-of-an-optical-signal-250x229.jpg 250w, https:\/\/www.optcore.net\/wp-content\/uploads\/depicts-OMA-in-a-stressed-eye-diagram-of-an-optical-signal-436x400.jpg 436w, https:\/\/www.optcore.net\/wp-content\/uploads\/depicts-OMA-in-a-stressed-eye-diagram-of-an-optical-signal-500x458.jpg 500w\" sizes=\"auto, (max-width: 517px) 100vw, 517px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Prueba de sensibilidad del receptor<\/h3>\n\n\n\n<p>La sensibilidad de recepci\u00f3n es uno de los par\u00e1metros clave para medir el rendimiento de los dispositivos receptores de transceptores \u00f3pticos.&nbsp;La prueba de sensibilidad de recepci\u00f3n requiere la atenuaci\u00f3n de potencia de la se\u00f1al a trav\u00e9s de un atenuador \u00f3ptico programable, que permite completar el transceptor \u00f3ptico que recibe se\u00f1ales de diferente potencia comparando la tasa de error de diferente potencia \u00f3ptica por el medidor de error.&nbsp;Entre ellos, cuanto mejor sea la sensibilidad de recepci\u00f3n, menor ser\u00e1 la potencia lum\u00ednica m\u00ednima de recepci\u00f3n.&nbsp;Por el contrario, si la sensibilidad de recepci\u00f3n es mala, mayores ser\u00e1n los requisitos para el dispositivo receptor \u00f3ptico.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prueba de diagrama de ojo del transceptor<\/h3>\n\n\n\n<p>Los diagramas de ojos son una herramienta com\u00fan para ver las salidas del transmisor.&nbsp;Proporciona una gran cantidad de informaci\u00f3n sobre el rendimiento general del transmisor.&nbsp;En un diagrama de ojo, todas las combinaciones de patrones de datos se superponen en una l\u00ednea de tiempo com\u00fan, generalmente per\u00edodos de menos de dos bits.&nbsp;La figura 1 muestra una se\u00f1al con buena amplitud y baja fluctuaci\u00f3n.&nbsp;Puede imaginar c\u00f3mo se construye el diagrama de ojo dibujando ocho posibles secuencias de formas de onda de tres bits (000,001,\u2026 110, 111) superpuestas en una l\u00ednea de tiempo com\u00fan.<\/p>\n\n\n\n<p>En lugar de realizar varias mediciones, puede utilizar la prueba de la m\u00e1scara ocular para determinar la calidad del ojo.&nbsp;La m\u00e1scara consta de varios pol\u00edgonos colocados en el diagrama de ojo y en el diagrama de ojo, que indican \u00e1reas donde las formas de onda no deben cruzarse.&nbsp;La forma de onda \u00abbuena\u00bb nunca se cruzar\u00e1 con la plantilla, y la forma de onda \u00abmala\u00bb cruzar\u00e1 o violar\u00e1 la plantilla.&nbsp;Retroceda y vea la vista a nivel del sistema, abrir un ojo indica que el receptor distinguir\u00e1 f\u00e1cilmente entre Logic 1 y Logic 0. Si cierra los ojos, aumenta la probabilidad de error (error).&nbsp;La Figura 2 muestra las formas de onda que son f\u00e1ciles de pasar la prueba de m\u00e1scara ocular.<\/p>\n\n\n\n<p>El osciloscopio de banda ancha le permite realizar pruebas de m\u00e1scara ocular \u00f3ptica.&nbsp;Estos instrumentos tienen varios nombres, incluidos los analizadores de comunicaciones digitales.&nbsp;El osciloscopio puede realizar pruebas y determinar si alguna muestra de forma de onda ha aterrizado en la plantilla.<\/p>\n\n\n\n<p>Los fabricantes de l\u00e1ser quieren que sus l\u00e1seres pasen las pruebas de m\u00e1scara sin irregularidades y quieren encontrar mediciones con margen suficiente.&nbsp;Ampliar el tama\u00f1o de la m\u00e1scara tanto como sea posible proporciona el m\u00e1ximo equilibrio sin incurrir en golpes de m\u00e1scara.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Relaci\u00f3n cruzada del ojo del transceptor (cruce)<\/h3>\n\n\n\n<p>La relaci\u00f3n cruzada de la tabla optom\u00e9trica es la relaci\u00f3n entre la amplitud de medici\u00f3n de la intersecci\u00f3n y los bits de la se\u00f1al \u00ab1\u00bb y \u00ab0\u00bb, por lo que diferentes relaciones entre escalas pueden transmitir diferentes bits de se\u00f1al.&nbsp;El&nbsp;transmisor&nbsp;<a href=\"https:\/\/www.optcore.net\/product-category\/sfp-transceiver\/\">transceptor \u00f3ptico SFP<\/a>&nbsp;est\u00e1ndar&nbsp;tiene una relaci\u00f3n de cruce del 50%, lo que significa que el c\u00f3digo \u00ab1\u00bb l\u00f3gico de la se\u00f1al \u00f3ptica y el c\u00f3digo \u00ab0\u00bb l\u00f3gico representan la mitad de los bits, respectivamente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Transceptor Jitter Time (RMS)<\/h3>\n\n\n\n<p>El tiempo de fluctuaci\u00f3n es el per\u00edodo durante el cual se transmite el ruido temporizado generado por la transmisi\u00f3n de se\u00f1ales \u00f3pticas en el transmisor transceptor \u00f3ptico SFP.&nbsp;Minimice este tiempo de fluctuaci\u00f3n asociado en el transceptor \u00f3ptico SFP y mejore el rendimiento general del sistema.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prueba de corriente de polarizaci\u00f3n del transceptor<\/h3>\n\n\n\n<p>Para que el interruptor l\u00e1ser LD de alta velocidad funcione correctamente.&nbsp;Debe agregarse a la corriente de polarizaci\u00f3n de CC I BIAS, que es ligeramente mayor que la corriente de umbral ITH representada directamente por el sesgo.&nbsp;Si el BIAS es demasiado grande, los componentes del acelerador envejecer\u00e1n y, si el BIAS es demasiado peque\u00f1o, el l\u00e1ser no funcionar\u00e1 correctamente.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prueba de longitud de onda del transceptor<\/h3>\n\n\n\n<p>Dado que los m\u00f3dulos \u00f3pticos utilizados en los dispositivos en ambos extremos deben emitir la misma longitud de onda para establecer la comunicaci\u00f3n, el fabricante debe probar la longitud de onda del m\u00f3dulo \u00f3ptico antes del env\u00edo para asegurarse de que est\u00e9 dentro del rango de desviaci\u00f3n.&nbsp;Generalmente, los fabricantes usan analizadores de espectro \u00f3ptico y otros instrumentos para medir la longitud de onda central del m\u00f3dulo \u00f3ptico, y la longitud de onda central medida del m\u00f3dulo \u00f3ptico generalmente se desv\u00eda del valor est\u00e1ndar.&nbsp;Los diferentes tipos de m\u00f3dulos \u00f3pticos tienen diferentes desviaciones, pero siempre que la desviaci\u00f3n est\u00e9 dentro del rango permitido, por ejemplo, la longitud de onda central del&nbsp;m\u00f3dulo \u00f3ptico&nbsp;<a href=\"https:\/\/www.optcore.net\/product\/1g-sfp-lx-singlemode-transceiver\/\">SFP-1G-LX<\/a>&nbsp;es de 1310 nm, y su desviaci\u00f3n es de \u00b1 50 nm, y la longitud de onda central del&nbsp;<a href=\"https:\/\/www.optcore.net\/product\/msa-1g-sfp-sx-multimode-transceiver\/\">SFP-1G-SX<\/a>El m\u00f3dulo \u00f3ptico es de 850 nm y su desviaci\u00f3n es de \u00b1 10 nm.&nbsp;La longitud de onda central del&nbsp;m\u00f3dulo \u00f3ptico&nbsp;<a href=\"https:\/\/www.optcore.net\/product\/10gbs-cwdm-14701610nm-40km-sfp-er-optical-transceiver-module\/\">10G-CWDM-SFP-ER<\/a>&nbsp;es de 1470 nm y su desviaci\u00f3n es de \u00b1 7,5 nm.&nbsp;Si el valor probado no coincide con la especificaci\u00f3n est\u00e1ndar, el m\u00f3dulo \u00f3ptico se considera defectuoso.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prueba de compatibilidad del transceptor<\/h3>\n\n\n\n<p>La prueba de compatibilidad es principalmente para m\u00f3dulos \u00f3pticos compatibles.&nbsp;El m\u00f3dulo \u00f3ptico se inserta en el interruptor de los dispositivos de la marca correspondiente para su prueba.&nbsp;La comunicaci\u00f3n normal significa que el m\u00f3dulo \u00f3ptico ha pasado la prueba.&nbsp;Si no puede comunicarse, significa que el m\u00f3dulo \u00f3ptico no es compatible con \u00e9l.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Inspecci\u00f3n del extremo \u00f3ptico del transceptor<\/h3>\n\n\n\n<p>Los transceptores \u00f3pticos son muy variables en dise\u00f1o y tipo: por ejemplo&nbsp;,&nbsp;<a href=\"https:\/\/www.optcore.net\/product-category\/sfp-transceiver\/\">SFP<\/a>&nbsp;, SFP +, XFP, XENPAK, GBIC, QSFP +, etc. Los SFP, SFP + y XFP tienen una interfaz de conector LC;&nbsp;XENPAK, 1 * 9, GBIC tiene una interfaz SC.&nbsp;Los&nbsp;<a href=\"https:\/\/www.optcore.net\/product-category\/100g-qsfp28-transceiver\/\">transceptores<\/a>&nbsp;QSFP o&nbsp;<a href=\"https:\/\/www.optcore.net\/product-category\/100g-qsfp28-transceiver\/\">QSFP28<\/a>&nbsp;suelen tener una interfaz MPO \/ MTP o LC.<\/p>\n\n\n\n<p>Independientemente del tipo de fibra, aplicaci\u00f3n o velocidad de datos, la transmisi\u00f3n de la luz requiere una ruta clara junto con un enlace, incluso a trav\u00e9s de cualquier conexi\u00f3n pasiva o empalme en el camino.&nbsp;Una sola part\u00edcula en el n\u00facleo de una fibra puede causar p\u00e9rdidas y reflejos, lo que resulta en altas tasas de error y degradaci\u00f3n del rendimiento de la red.&nbsp;La contaminaci\u00f3n en el extremo de una fibra, como se muestra en la Figura 1, tambi\u00e9n puede afectar negativamente a la interfaz de equipos \u00f3pticos costosos y, en algunos casos, incluso hacer que el equipo no funcione.<\/p>\n\n\n\n<p>Al inspeccionar el extremo \u00f3ptico del transceptor, comprobaremos si hay suciedad y rayones.&nbsp;Dado que la contaminaci\u00f3n es la principal causa de falla de la fibra, todos los m\u00f3dulos \u00f3pticos se revisan adecuadamente antes del env\u00edo, incluso si esto agrega tiempo y dinero.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Verificaci\u00f3n de apariencia<\/h3>\n\n\n\n<p>Implica inspeccionar los m\u00f3dulos \u00f3pticos antes de enviarlos con fines de control de calidad.&nbsp;Revise la caja de cada m\u00f3dulo en busca de rayones, suciedad, color, suavidad, dedos dorados en busca de rayones y etiquetas.&nbsp;Por lo general, la apariencia deficiente del m\u00f3dulo del transceptor \u00f3ptico tambi\u00e9n ser\u00e1 defectuosa, mientras que la apariencia del transceptor de alta calidad es buena.<\/p>\n\n\n\n<p>Este art\u00edculo describe qu\u00e9 pruebas debe pasar un transceptor \u00f3ptico de alta calidad y qu\u00e9 significan estos enlaces y par\u00e1metros de prueba.&nbsp;Al leer, espero que pueda distinguir r\u00e1pidamente la calidad de un transceptor \u00f3ptico.&nbsp;Aseg\u00farese de elegir un transceptor \u00f3ptico de alta calidad que determine la estabilidad de su red y la calidad de transmisi\u00f3n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Conclusi\u00f3n<\/h3>\n\n\n\n<p>Este art\u00edculo describe qu\u00e9 pruebas debe pasar un transceptor \u00f3ptico de alta calidad y qu\u00e9 significan estos enlaces y par\u00e1metros de prueba.&nbsp;Al leer, espero que pueda distinguir r\u00e1pidamente la calidad de un transceptor \u00f3ptico.&nbsp;Aseg\u00farese de elegir un transceptor \u00f3ptico de alta calidad que determine la estabilidad de su red y la calidad de transmisi\u00f3n.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Es bien sabido que el&nbsp;transceptor \u00f3ptico&nbsp;es una parte importante de&nbsp;la red de&nbsp;comunicaci\u00f3n de&nbsp;fibra \u00f3ptica&nbsp;.&nbsp;Por lo general, todos est\u00e1n muy preocupados por el rendimiento del conmutador Ethernet, sin embargo, pueden ignorar la calidad de los componentes importantes: el transceptor \u00f3ptico, el precio se ha convertido en el \u00fanico factor en la compra.&nbsp;Pero la verdad es que&#8230;&#8230;<\/p>\n","protected":false},"author":1,"featured_media":42783,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[1329,5400],"tags":[965,1307],"class_list":["post-42802","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-transceptor-optico","tag-optical-transceiver","tag-optical-transceiver-es"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.7 (Yoast SEO v27.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico<\/title>\n<meta name=\"description\" content=\"Es bien sabido que el transceptor \u00f3ptico es una parte importante de la red de comunicaci\u00f3n de fibra \u00f3ptica . Por lo general, todos est\u00e1n muy preocupados por el rendimiento del conmutador Ethernet, sin embargo, pueden ignorar la calidad de los componentes importantes:\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico\" \/>\n<meta property=\"og:description\" content=\"Es bien sabido que el&nbsp;transceptor \u00f3ptico&nbsp;es una parte importante de&nbsp;la red de&nbsp;comunicaci\u00f3n de&nbsp;fibra \u00f3ptica&nbsp;.&nbsp;Por lo\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"Optcore\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/OPTCOREofficial\/\" \/>\n<meta property=\"article:published_time\" content=\"2021-02-20T09:49:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-23T03:02:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.optcore.net\/wp-content\/uploads\/Understanding-the-optical-transceiver-quality-testing.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"682\" \/>\n\t<meta property=\"og:image:height\" content=\"455\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Optcore\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Optcore\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/\"},\"author\":{\"name\":\"Optcore\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#\\\/schema\\\/person\\\/d09165236b6551b6c06da458891f57c0\"},\"headline\":\"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico\",\"datePublished\":\"2021-02-20T09:49:31+00:00\",\"dateModified\":\"2023-11-23T03:02:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/\"},\"wordCount\":2117,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.optcore.net\\\/wp-content\\\/uploads\\\/Understanding-the-optical-transceiver-quality-testing.jpg\",\"keywords\":[\"Optical Transceiver\",\"Transceptor \u00f3ptico\"],\"articleSection\":[\"Blog\",\"Transceptor \u00f3ptico\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/\",\"url\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/\",\"name\":\"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.optcore.net\\\/wp-content\\\/uploads\\\/Understanding-the-optical-transceiver-quality-testing.jpg\",\"datePublished\":\"2021-02-20T09:49:31+00:00\",\"dateModified\":\"2023-11-23T03:02:46+00:00\",\"description\":\"Es bien sabido que el transceptor \u00f3ptico es una parte importante de la red de comunicaci\u00f3n de fibra \u00f3ptica . Por lo general, todos est\u00e1n muy preocupados por el rendimiento del conmutador Ethernet, sin embargo, pueden ignorar la calidad de los componentes importantes:\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.optcore.net\\\/wp-content\\\/uploads\\\/Understanding-the-optical-transceiver-quality-testing.jpg\",\"contentUrl\":\"https:\\\/\\\/www.optcore.net\\\/wp-content\\\/uploads\\\/Understanding-the-optical-transceiver-quality-testing.jpg\",\"width\":682,\"height\":455},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/understanding-the-optical-transceiver-quality-testing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/\",\"name\":\"Optcore.net\",\"description\":\"Optical Transceiver and Fiber Optic Solution Provider\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#organization\"},\"alternateName\":\"Optcore\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#organization\",\"name\":\"OPTCORE Espa\u00f1a\",\"alternateName\":\"Optcore\",\"url\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.optcore.net\\\/wp-content\\\/uploads\\\/optcore-logo4.png\",\"contentUrl\":\"https:\\\/\\\/www.optcore.net\\\/wp-content\\\/uploads\\\/optcore-logo4.png\",\"width\":220,\"height\":45,\"caption\":\"OPTCORE Espa\u00f1a\"},\"image\":{\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/OPTCOREofficial\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/optcore-technology-co--ltd\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/#\\\/schema\\\/person\\\/d09165236b6551b6c06da458891f57c0\",\"name\":\"Optcore\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/eee379750fb655387b8dc1c68a7785142f4f6970eed1dea28aeca34192ae8e29?s=96&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/eee379750fb655387b8dc1c68a7785142f4f6970eed1dea28aeca34192ae8e29?s=96&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/eee379750fb655387b8dc1c68a7785142f4f6970eed1dea28aeca34192ae8e29?s=96&r=g\",\"caption\":\"Optcore\"},\"url\":\"https:\\\/\\\/www.optcore.net\\\/es\\\/author\\\/optcorewp512\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico","description":"Es bien sabido que el transceptor \u00f3ptico es una parte importante de la red de comunicaci\u00f3n de fibra \u00f3ptica . Por lo general, todos est\u00e1n muy preocupados por el rendimiento del conmutador Ethernet, sin embargo, pueden ignorar la calidad de los componentes importantes:","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/","og_locale":"es_ES","og_type":"article","og_title":"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico","og_description":"Es bien sabido que el&nbsp;transceptor \u00f3ptico&nbsp;es una parte importante de&nbsp;la red de&nbsp;comunicaci\u00f3n de&nbsp;fibra \u00f3ptica&nbsp;.&nbsp;Por lo","og_url":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/","og_site_name":"Optcore","article_publisher":"https:\/\/www.facebook.com\/OPTCOREofficial\/","article_published_time":"2021-02-20T09:49:31+00:00","article_modified_time":"2023-11-23T03:02:46+00:00","og_image":[{"width":682,"height":455,"url":"https:\/\/www.optcore.net\/wp-content\/uploads\/Understanding-the-optical-transceiver-quality-testing.jpg","type":"image\/jpeg"}],"author":"Optcore","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Optcore","Tiempo de lectura":"10 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#article","isPartOf":{"@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/"},"author":{"name":"Optcore","@id":"https:\/\/www.optcore.net\/es\/#\/schema\/person\/d09165236b6551b6c06da458891f57c0"},"headline":"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico","datePublished":"2021-02-20T09:49:31+00:00","dateModified":"2023-11-23T03:02:46+00:00","mainEntityOfPage":{"@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/"},"wordCount":2117,"commentCount":0,"publisher":{"@id":"https:\/\/www.optcore.net\/es\/#organization"},"image":{"@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.optcore.net\/wp-content\/uploads\/Understanding-the-optical-transceiver-quality-testing.jpg","keywords":["Optical Transceiver","Transceptor \u00f3ptico"],"articleSection":["Blog","Transceptor \u00f3ptico"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/","url":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/","name":"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico","isPartOf":{"@id":"https:\/\/www.optcore.net\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#primaryimage"},"image":{"@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#primaryimage"},"thumbnailUrl":"https:\/\/www.optcore.net\/wp-content\/uploads\/Understanding-the-optical-transceiver-quality-testing.jpg","datePublished":"2021-02-20T09:49:31+00:00","dateModified":"2023-11-23T03:02:46+00:00","description":"Es bien sabido que el transceptor \u00f3ptico es una parte importante de la red de comunicaci\u00f3n de fibra \u00f3ptica . Por lo general, todos est\u00e1n muy preocupados por el rendimiento del conmutador Ethernet, sin embargo, pueden ignorar la calidad de los componentes importantes:","breadcrumb":{"@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#primaryimage","url":"https:\/\/www.optcore.net\/wp-content\/uploads\/Understanding-the-optical-transceiver-quality-testing.jpg","contentUrl":"https:\/\/www.optcore.net\/wp-content\/uploads\/Understanding-the-optical-transceiver-quality-testing.jpg","width":682,"height":455},{"@type":"BreadcrumbList","@id":"https:\/\/www.optcore.net\/es\/understanding-the-optical-transceiver-quality-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.optcore.net\/es\/"},{"@type":"ListItem","position":2,"name":"Comprensi\u00f3n de las pruebas de calidad del transceptor \u00f3ptico"}]},{"@type":"WebSite","@id":"https:\/\/www.optcore.net\/es\/#website","url":"https:\/\/www.optcore.net\/es\/","name":"Optcore.net","description":"Optical Transceiver and Fiber Optic Solution Provider","publisher":{"@id":"https:\/\/www.optcore.net\/es\/#organization"},"alternateName":"Optcore","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.optcore.net\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.optcore.net\/es\/#organization","name":"OPTCORE Espa\u00f1a","alternateName":"Optcore","url":"https:\/\/www.optcore.net\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.optcore.net\/es\/#\/schema\/logo\/image\/","url":"https:\/\/www.optcore.net\/wp-content\/uploads\/optcore-logo4.png","contentUrl":"https:\/\/www.optcore.net\/wp-content\/uploads\/optcore-logo4.png","width":220,"height":45,"caption":"OPTCORE Espa\u00f1a"},"image":{"@id":"https:\/\/www.optcore.net\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/OPTCOREofficial\/","https:\/\/www.linkedin.com\/company\/optcore-technology-co--ltd\/"]},{"@type":"Person","@id":"https:\/\/www.optcore.net\/es\/#\/schema\/person\/d09165236b6551b6c06da458891f57c0","name":"Optcore","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/eee379750fb655387b8dc1c68a7785142f4f6970eed1dea28aeca34192ae8e29?s=96&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/eee379750fb655387b8dc1c68a7785142f4f6970eed1dea28aeca34192ae8e29?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/eee379750fb655387b8dc1c68a7785142f4f6970eed1dea28aeca34192ae8e29?s=96&r=g","caption":"Optcore"},"url":"https:\/\/www.optcore.net\/es\/author\/optcorewp512\/"}]}},"_links":{"self":[{"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/posts\/42802","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/comments?post=42802"}],"version-history":[{"count":0,"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/posts\/42802\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/media\/42783"}],"wp:attachment":[{"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/media?parent=42802"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/categories?post=42802"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.optcore.net\/es\/wp-json\/wp\/v2\/tags?post=42802"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}